Chauvin Arnoux CA1631 Current & Voltage Calibrator 0 → 24 mA


Compact and simple to use, the CA 1631 calibrator is equipped with a wide screen for comfortable reading.

The CA 1631 can be used to measure and supply a DC current loop from 0 to 24 mA with 0.015% accuracy and a DC voltage between 0 and 20 V with an accuracy of +/- 0.02 %.

When used as a battery-powered stand-alone instrument, it offers a long battery life in the field. When connected to the mains, it can be used continuously without any time limit.


Share it:
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.

 

Instruments for use in developing and verifying measurement chains
CA1621 temperature calibrator for J,K,T,E,R,S,B,N thermocouples and voltage in mV
CA1623 temperature calibrator for Pt10,Pt50,Pt100,Pt200,Pt500,Pt1000 and Pt1000(JIS) probes and resistance
CA1631 current loop calibrator for measuring and supplying DC current loop 0 to 24mA, dc voltage between 0 and 20V
Calibrator dimensions 205 x 97 x 45mm
Calibrator weight 472g (including batteries)

 

Supplied with

Test wires (2 pairs), crocodile clip, 6AAA 1.5V batteries (6), operating manual in 5 languages, carrying case

Specifications:

Attribute
Value
Calibrated UKAS
Absolute Maximum Voltage Measurement 20V dc
Absolute Maximum Current Measurement 24mA
Best Accuracy ±0.015 %
Power Source Battery, Mains
Battery Type AAA
Dimensions 205 x 98 x 46mm
Weight 472g
Length 205mm
Maximum Operating Temperature +55°C
Maximum Source Current 24mA
Minimum Operating Temperature -10°C
Maximum Source Voltage 0 mA, 20 V
Minimum Source Voltage 0V
Minimum Source Current 0mA
Model Number p CA 1631

Reviews

There are no reviews yet.

Be the first to review “Chauvin Arnoux CA1631 Current & Voltage Calibrator 0 → 24 mA”

Your email address will not be published. Required fields are marked *

Custom Tab Content here.